Summary for Test 2020-02-11-2-3
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213489 Permit Numbers: 0817NMC1320 0819NRT0801 0819NRW0944 0819NRT0802 0819NRW0952 0819NRW1158 0819NRW1299 0820NRT0046 0820NRT0047 |
---|---|
DIST-CO-RTE-PM | 08---27.05/27.55 |
Award Date | 06/01/2018 |
Closeout Date | 06/23/2021 |
Work Description | Enter onto Interstate 10 (I-10) right of way at Mountain View Avenue in the City of Redlands, to perform I-10 EB and WB off-ramps widening, install curb and gutter, ADA curb ramps, modify existing traffic signal, extend drainage box culvert, and install erosion control as per plans and specificatio |
Location Description | I-10, EB and WB off-ramps, Loma Linda |
QA Service Level | 1 (Verified on 08/13/2019) |
Sample Information
Sample Taken Date | 02/11/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/14/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"-10 x 15" x 3" |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | Telephone number of sampler | 213 435 4055 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-044-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3093312 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Grade 55 | |
Bolt Length(s) | 15" x 3" | Nut Specification | n/a |
Washer Specification | n/a | Finish | Hot Dipped Galvanized |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-02-11-2
DIME Test ID: 2020-02-11-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-02-18
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 02/14/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 3093312
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: .75 in
Bolt Length: 15 in
Measurement Average: 5.09 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/18/2020 ✔