Summary for Test 2017-12-22-21-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date12/22/2017 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2017
Sample typeVerification A brief description of the sample3 4 in Aggregate Sample
The quantity of what the sample constitutesUnknown Quantity From where was the sample collectedSource
First name of sampler or witnessed byAggregate First Name Last name of sampler or witnessed byAggregate Last Name
Title of samplerAggregate Engineer Telephone number of sampler7753550420
Laboratory sample identificationAggregate Sample ID Linked DIME Sample IDAggregate DIME Sample ID
The fabricator/manufacturer/facility nameSNC Mustang Pit Sparks NV Transportation Laboratory (TL) NumberAggregate TL Number
Inspector Lot Number from the Transportation Laboratory (TL) FormAggregate TL Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Aggregate Source ID
The fabricator's/manufacturer's product name for the sampleSNC Mustang Pit Sparks NV The fabricator/manufacturer designation for the sampleSNC Mustang Pit Sparks NV
The plant number99999 A detailed description of where the material sample was collectedCoarse aggregate pile at source
Where the material sample would have been placed if not sampled7753550420 Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2017-12-22-21
DIME Test ID: 2017-12-22-21-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-01-10

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: David Phong
Date of test: 01/02/2020
Cumulative percent passing the 1 1/2 in. sieve: 0 %
Cumulative percent passing the 1 in. sieve: 0 %
Cumulative percent passing the 3/4 in. sieve: 0 %
Cumulative percent passing the 1/2 in. sieve: 0 %
Cumulative percent passing the 3/8 in. sieve: 0 %
Cumulative percent passing the 1/4 in. sieve: 0 %
Cumulative percent passing the #4 sieve: 0 %
Cumulative percent passing the #8 sieve: 0 %
Cumulative percent passing the #16 sieve: 0 %
Cumulative percent passing the #30 sieve: 0 %
Cumulative percent passing the #50 sieve: 0 %
Cumulative percent passing the #100 sieve: 0 %
Cumulative percent passing the #200 sieve: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/10/2020