Summary for Test 2019-02-22-14-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date02/22/2019 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/22/2019
Sample typeVerification A brief description of the sample1/2" Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byDan Last name of sampler or witnessed byWeaver
Title of sampler Telephone number of sampler
Laboratory sample identification19-J-002 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Pacific - Avenal Transportation Laboratory (TL) NumberC955245
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA or name of Pit)91-10-0006
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSource
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-02-22-14
DIME Test ID: 2019-02-22-14-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-12-31

Test Results


What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 02/22/2019
Total mass of material in the sample: 12998 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 694 grams
Cumulative mass retained on the 3/8 in. sieve: 2938 grams
Cumulative mass retained on the 1/4 in. sieve: 7222 grams
Cumulative mass retained on the #4 sieve: 9495 grams
Cumulative mass retained on the #8 sieve: 363 grams
Cumulative mass retained on the #16 sieve: 392.4 grams
Cumulative mass retained on the #30 sieve: 436.3 grams
Cumulative mass retained on the #50 sieve: 462.3 grams
Cumulative mass retained on the #100 sieve: 488.6 grams
Cumulative mass retained on the #200 sieve: 495.5 grams
Cumulative mass retained on the pan: no data
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 94.7 %
Cumulative percent passing the 3/8 in. sieve: 77.4 %
Cumulative percent passing the 1/4 in. sieve: 44.4 %
Cumulative percent passing the #4 sieve: 27 %
Cumulative percent passing the #8 sieve: 8.2 %
Cumulative percent passing the #16 sieve: 6.7 %
Cumulative percent passing the #30 sieve: 4.4 %
Cumulative percent passing the #50 sieve: 3.1 %
Cumulative percent passing the #100 sieve: 1.7 %
Cumulative percent passing the #200 sieve: 1.37 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/31/2019