Summary for Test 2019-04-01-49-3
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 04/01/2019 | Sample Unique Key | 49 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2019 |
Sample type | Verification | A brief description of the sample | 1/2" RHMA-G, PG 64-16 w/1% Lime Slurry |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
First name of sampler or witnessed by | Barrett | Last name of sampler or witnessed by | Felder |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-01-49
DIME Test ID: 2019-04-01-49-3
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-12-03
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 04/01/2019
1 | 2 | 3 | ||||
---|---|---|---|---|---|---|
2.385 | 2.394 | 2.393 | ||||
2.505 | ||||||
4.8 % | 4.4 % | 4.5 % | ||||
4.6 % |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/3/2019 ✔