Summary for Test 2019-10-11-11-10

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 213745
DEA: 080Q1204
EFIS: 0800020125
DIST-CO-RTE-PM08-SBD-18-99.5-100.9
Award Date02/19/2019
Closeout Date03/24/2020
Work DescriptionWIDEN ROADBED AND CONSTRUCT RAISED CURB MEDIAN
Location DescriptionSAN BERNARDINO COUNTY FROM COBALT ROAD TO ROUTE 395
QA Service Level1 (Verified on 04/02/2019)

Sample Information

Sample Taken Date10/11/2019 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/17/2019
Sample typeVerification A brief description of the sample1 HMA-A-SP R15
The quantity of what the sample constitutesPSUE 5 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byBlue Diamond Materials Victorville Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0633A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAgcon-Oro Grande, Cemex-White Mountain Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0046, 91-36-0106
The fabricator's/manufacturer's product name for the sample1 HMA-A-SP R15 The fabricator/manufacturer designation for the sample300222
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-10-11-11
DIME Test ID: 2019-10-11-11-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-05-07

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Michael Magana, Husni Ankir
Date of test: 10/29/2019
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 91 %
Cumulative percent passing the 1/2 in. sieve: 73 %
Cumulative percent passing the 3/8 in. sieve: 67 %
Cumulative percent passing the #4 sieve: 53 %
Cumulative percent passing the #8 sieve: 41 %
Cumulative percent passing the #16 sieve: 30 %
Cumulative percent passing the #30 sieve: 20 %
Cumulative percent passing the #50 sieve: 11 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 3.2 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate/RAP Gradation w/Correlation Factors Applied

Test was verified on 5/7/2020