Summary for Test 2019-10-31-7-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 214136 DEA: 010F3604 EFIS: 0115000115 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-R39.2/R48.3 |
Award Date | 07/31/2019 |
Closeout Date | 01/04/2021 |
Work Description | COLD PLANE AC PAVEMENT, RHMA OVERLAY, AND GUARDRAIL INSTALLATION. |
Location Description | HUMBOLDT COUNTY NEAR REDCREST, PEPPERWOOD, AND STAFFORD FROM ENGLWOOD PARK UNDERCROSSING TO EEL RIVER BRIDGE AND OVERHEAD |
QA Service Level | 1 (Verified on 06/24/2019) |
Sample Information
Sample Taken Date | 10/31/2019 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2019 |
Sample type | Verification | A brief description of the sample | 1/2" RHMA-G |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Andy | Last name of sampler or witnessed by | Eggink |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 19-261 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mercer Fraser B | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-10-31-7
DIME Test ID: 2019-10-31-7-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-11-05
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 11/05/2019
Specific Gravity for Sample 1: 2.382
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/5/2019 ✔