Summary for Test 2019-10-30-2-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625 |
---|---|
DIST-CO-RTE-PM | 08-RIV-15-34.7/51.6 |
Award Date | 04/17/2017 |
Closeout Date | Not set |
Work Description | (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT |
Location Description | Riverside County and SBD-15-0.0/1.3 |
QA Service Level | 1 (Verified on 05/08/2017) |
Sample Information
Sample Taken Date | 10/30/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolts |
The quantity of what the sample constitutes | 24 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Foerder |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SLSB | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B285-078-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 20372980 20403620 188648 284755 172978 | Nut Mfg. Lot Number(s) | 29747-S-188648 |
Washer Mfg. Lot Number(s) | D7245 01339A | Bolt Specification | A325 |
Bolt Length(s) | 6" | Nut Specification | A563 |
Washer Specification | F436 F959 DTI | Finish | MG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | BM0169 BM0269 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-10-30-2
DIME Test ID: 2019-10-30-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-11-05
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/05/2019
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2B | BM0269 | 1.0000 | 83508 | 371.46 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 11/5/2019 ✔