Summary for Test 2014-08-14-23-4
Test performed: CTM 301-March 2000Project Information
Project Identifiers | Project ID: 7427 DEA: 07215934 EFIS: 0700001833 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-2.4/4.0 |
Award Date | 08/14/2012 |
Closeout Date | 02/20/2020 |
Work Description | Widen and Realign Freeway and Construct Ped OC, OC and UC Structures. |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING |
QA Service Level | 1 (Verified on 11/26/2012) |
Sample Information
Sample Taken Date | 08/14/2014 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/14/2014 |
Sample type | Department Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Other |
First name of sampler or witnessed by | Syed | Last name of sampler or witnessed by | Shah |
Title of sampler | ARE | Telephone number of sampler | Unknown |
Laboratory sample identification | 4233B | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | I 5 Mainline at Sta 168 50 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | I 5 Mainline at Sta 168 50 |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-08-14-23
DIME Test ID: 2014-08-14-23-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2015-02-20
Test Results
How will the R value be determined?: By expansion pressure
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 08/25/2014
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 97 %
As Received Gradation, Percent Passing 1/2 in. sieve: 80 %
As Received Gradation, Percent Passing 3/8 in. sieve: 69 %
As Received Gradation, Percent Passing #4 sieve: 52 %
As Received Gradation, Percent Passing #8 sieve: 43 %
As Received Gradation, Percent Passing #16 sieve: 35 %
As Received Gradation, Percent Passing #30 sieve: 25 %
As Received Gradation, Percent Passing #50 sieve: 17 %
As Received Gradation, Percent Passing #100 sieve: 10 %
As Received Gradation, Percent Passing #200 sieve: 6.2 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 82 %
As Used Gradation, Percent Passing 3/8 in. sieve: 71 %
As Used Gradation, Percent Passing #4 sieve: 54 %
As Used Gradation, Percent Passing #8 sieve: 45 %
As Used Gradation, Percent Passing #16 sieve: 36 %
As Used Gradation, Percent Passing #30 sieve: 26 %
As Used Gradation, Percent Passing #50 sieve: 17 %
As Used Gradation, Percent Passing #100 sieve: 10 %
As Used Gradation, Percent Passing #200 sieve: 6.5 %
R value: 80
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔