Summary for Test 2014-08-20-22-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 208679 DEA: 100S1104 EFIS: 1000000229 COOP: 10406 |
---|---|
DIST-CO-RTE-PM | 10-SJ-4,5-Var |
Award Date | 12/16/2013 |
Closeout Date | 01/03/2019 |
Work Description | SR-4 FREEWAY EXTENSION |
Location Description | IN SAN JOAQUIN COUNTY |
QA Service Level | 1 (Verified on 03/25/2013) |
Sample Information
Sample Taken Date | 08/20/2014 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/16/2014 |
Sample type | Quality Control | A brief description of the sample | concrete cylinder |
The quantity of what the sample constitutes | Unknown | From where was the sample collected | Other |
First name of sampler or witnessed by | Fernam | Last name of sampler or witnessed by | Rosal |
Title of sampler | QCconfab | Telephone number of sampler | 000-000-0000 |
Laboratory sample identification | cl141085 | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | field | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Unknown | |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | na |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | field | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-08-20-22
DIME Test ID: 2014-08-20-22-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-09-17
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 09/17/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 296546 lb
Maximum load on cylinder 2: 289253 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 10594.7 psi
Compressive strength of cylinder 2: 10297.4 psi
Compressive strength (to nearest 10 psi): 10450 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/17/2014 ✔