Summary for Test 2019-09-04-10-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 213856 DEA: 112888U4 EFIS: 1118000199 |
---|---|
DIST-CO-RTE-PM | 11-SD-11,125,905-Various |
Award Date | 05/09/2019 |
Closeout Date | 09/14/2023 |
Work Description | CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY |
Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 09/04/2019 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/16/2019 |
Sample type | Quality Assurance | A brief description of the sample | #14 10A Doughnut Headed Bars |
The quantity of what the sample constitutes | 8 of 225 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9168691602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Integrity Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-216-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 033695 | Head Manufacturer Lot Number(s) | A192336, MM18107398 |
Rebar Size | 14 | Headed Bar Model Name | 10A Doughnut Taper |
Size of Head | Full Size - 9x | Head Connection Type | Taper Threaded |
Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | Bar Splice | Head Fabricator | Integrity Rebar |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2019-09-04-10
DIME Test ID: 2019-09-04-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-10-17
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/17/2019
UTM: 2000kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 2.25 | 229697.49 | 102088 | Bar Broke, Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/17/2019 ✔