Summary for Test 2019-09-27-12-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 212993 DEA: 033F5304 EFIS: 0313000135 |
|---|---|
| DIST-CO-RTE-PM | 03-ED-50-67.3 |
| Award Date | 11/09/2018 |
| Closeout Date | 09/20/2022 |
| Work Description | ECHO SUMMIT BRIDGE IS A 24-FT WIDE, THREE-SPAN, REINFORCED CONCRETE GIRDER BRIDGE |
| Location Description | EL DORADO COUNTY NEAR MEYERS AT ECHO SUMMIT SIDEHILL VIADUCT |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 09/27/2019 | Sample Unique Key | 12 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/03/2019 |
| Sample type | Quality Assurance | A brief description of the sample | Headed Bars |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor Dextra | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 3500006213 | Head Manufacturer Lot Number(s) | 010276 |
| Rebar Size | 7 | Headed Bar Model Name | Dextra Large Anchor Plates |
| Size of Head | Reduced Size - 4x | Head Connection Type | Threaded |
| Head Shape | Circular | Rebar Manufacturer | Nucor |
| Head Manufacturer | Dextra | Head Fabricator | Dextra |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2019-09-27-12
DIME Test ID: 2019-09-27-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-10-04
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/03/2019
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.6 | 57268 | 95447 | Bar Broke, Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/4/2019 ✔