Summary for Test 2019-08-21-14-3
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 213396 DEA: 060Q1804 EFIS: 0613000145 |
---|---|
DIST-CO-RTE-PM | 06-KER-58-R94.2 |
Award Date | 12/19/2018 |
Closeout Date | 10/15/2020 |
Work Description | TO INSTALL BRIDGE RAILING AND MIDWEST GUARDRAIL SYSTEM. |
Location Description | KERN COUNTY IN TEHACHAPI AT SUMMIT OVERHEAD |
QA Service Level | 1 (Verified on 06/05/2018) |
Sample Information
Sample Taken Date | 08/21/2019 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2019 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Adlai | Last name of sampler or witnessed by | Evans |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | 995-821 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | READY MIX | Transportation Laboratory (TL) Number | 20190821 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Overhang 3 to 9 75 on existng bridge deck |
Material Information
Material Type | Concrete | The concrete mix design number | 0H40X006 |
---|---|---|---|
The truck number from where the sample was collected | na | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Granite |
A detailed description of where the material sample was collected | truck | Where the material sample would have been placed if not sampled | Overhang 3 to 9 75 on existng bridge deck |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-08-21-14
DIME Test ID: 2019-08-21-14-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-10-02
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 10/02/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 161230 lb
Maximum load on cylinder 2: 161070 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 5665.1 psi
Compressive strength of cylinder 2: 5659.5 psi
Compressive strength (to nearest 10 psi): 5660 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/2/2019 ✔