Summary for Test 2019-09-25-1-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 214111 DEA: 081J5604 |
---|---|
DIST-CO-RTE-PM | 08-RIV-15,74,79-VAR. |
Award Date | 06/13/2019 |
Closeout Date | 06/23/2021 |
Work Description | REPLACE AC SURFACING AND PLACE RHMA-G. |
Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 10/08/2019) |
Sample Information
Sample Taken Date | 09/25/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/25/2019 |
Sample type | Acceptance | A brief description of the sample | AC Drum Aggregate |
The quantity of what the sample constitutes | 1 bag combined aggregate | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Idris | Last name of sampler or witnessed by | Najjar |
Title of sampler | TE Civil | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | All American Asphalt Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0027::CORONA QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | belt an chute |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | 106835 | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-25-1
DIME Test ID: 2019-09-25-1-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-10-07
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Seyed Mirgati
Date of test: 09/25/2019
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 85 %
Cumulative percent passing the 3/8 in. sieve: 69 %
Cumulative percent passing the #4 sieve: 29 %
Cumulative percent passing the #8 sieve: 12 %
Cumulative percent passing the #16 sieve: 9 %
Cumulative percent passing the #30 sieve: 7 %
Cumulative percent passing the #50 sieve: 6 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/7/2019 ✔