Summary for Test 2019-09-30-2-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213702 DEA: 041G4304 EFIS: 0412000126 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-R7.4 |
Award Date | 03/29/2019 |
Closeout Date | 12/08/2022 |
Work Description | REPLACE BRIDGE, HMA PAVING, DRAINAGE AND RSP |
Location Description | NAPA COUNTY NEAR SAINT HELENA AT CONN CREEK |
QA Service Level | 1 (Verified on 07/29/2019) |
Sample Information
Sample Taken Date | 09/30/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2019 |
Sample type | Quality Assurance | A brief description of the sample | #6 X 2'-7" Dia Hoops |
The quantity of what the sample constitutes | 3 lots with a total 314 pcs | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Dsouza |
Title of sampler | QA Inspector | Telephone number of sampler | 9492751713 |
Laboratory sample identification | Linked DIME Sample ID | 2019-09-30-1 | |
The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L132-032-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | 4089775 |
Hoop Manufacturer Lot Number(s) | Lot 1-3 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 2'-7" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | cmc steel Arizona |
Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-09-30-2
DIME Test ID: 2019-09-30-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-10-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/01/2019
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | 6/19mm | 0.44 | 42384.79 | 96329 | Bar Broke, Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/1/2019 ✔