Summary for Test 2019-08-02-26-2
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 214344 DEA: 120P42U4 EFIS: 1216000097 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5,22,55,57,91,405-Var |
Award Date | 09/15/2020 |
Closeout Date | Not set |
Work Description | Upgrade and install Intelligent Transportation System (ITS) elements |
Location Description | ORANGE COUNTY |
QA Service Level | 1 (Verified on 10/27/2020) |
Sample Information
Sample Taken Date | 08/02/2019 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/08/2019 |
Sample type | Per Request | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 Ziplock bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kristopher | Last name of sampler or witnessed by | Barker |
Title of sampler | Engineering Geologist | Telephone number of sampler | 909-806-4701 |
Laboratory sample identification | 8673 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | K-0P42U-1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Boring No. HA-2 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-08-02-26
DIME Test ID: 2019-08-02-26-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-18
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Tess Perez
Date of test: 08/13/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 4600 Ohms
Soil sample temperature: 21.7 C
Soil box constant: 1
pH of soil: 7.8
Minimum soil resistance corrected to 15.5: 5313 Ohms
Minimum soil resistivity at 15.5: 5313 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life = 50 years
Test was verified on 9/18/2019 ✔