Summary for Test 2019-06-27-31-9

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214342
DEA: 081F9904
EFIS: 0815000095
DIST-CO-RTE-PM08-SBD-15-40.1/40.5
Award Date06/15/2020
Closeout Date08/02/2021
Work DescriptionLENGTHEN ACCELERATION LANE
Location DescriptionVICTORVILLE FROM 0.5 MILE TO 0.1 MILE SOUTH OF PALMDALE ROAD OVERCROSSING
QA Service Level1 (Verified on 10/06/2020)

Sample Information

Sample Taken Date06/27/2019 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2019
Sample typeInformational A brief description of the sampleSoil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byGuzman
Title of samplerMREA Telephone number of sampler909-829-6292
Laboratory sample identification8647 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) Number8647
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedA-19-002
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-06-27-31
DIME Test ID: 2019-06-27-31-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-16

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 07/19/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 6200 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 8.22
Minimum soil resistance corrected to 15.5: 7192 Ohms
Minimum soil resistivity at 15.5: 7192 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life = 56 Years

Test was verified on 9/16/2019