Summary for Test 2019-06-27-31-9
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 214342 DEA: 081F9904 EFIS: 0815000095 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-40.1/40.5 |
Award Date | 06/15/2020 |
Closeout Date | 08/02/2021 |
Work Description | LENGTHEN ACCELERATION LANE |
Location Description | VICTORVILLE FROM 0.5 MILE TO 0.1 MILE SOUTH OF PALMDALE ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/06/2020) |
Sample Information
Sample Taken Date | 06/27/2019 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/15/2019 |
Sample type | Informational | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Guzman |
Title of sampler | MREA | Telephone number of sampler | 909-829-6292 |
Laboratory sample identification | 8647 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | 8647 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | A-19-002 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-06-27-31
DIME Test ID: 2019-06-27-31-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-16
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 07/19/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 6200 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 8.22
Minimum soil resistance corrected to 15.5: 7192 Ohms
Minimum soil resistivity at 15.5: 7192 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life = 56 Years
Test was verified on 9/16/2019 ✔