Summary for Test 2019-08-30-1-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 213762 DEA: 032F3404 EFIS: 0300020616 |
---|---|
DIST-CO-RTE-PM | 03-PLA-49-3.1/7.5 |
Award Date | 02/28/2019 |
Closeout Date | 05/11/2022 |
Work Description | WIDEN SHOULDERS, ADD RETAINING WALLS, REPLACE MBGR, CURBS & ELECTRICAL |
Location Description | PLACER COUNTY IN AND NEAR AUBURN FROM 0.1 MILE SOUTH OF ROUTE 49/80 SEPARATION TO 0.1 MILE NORTH OF DRY CREEK ROAD |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 08/30/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/04/2019 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | A | Last name of sampler or witnessed by | wankhede |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | 174001 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | Z5635256 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 000000 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Job site | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-08-30-1
DIME Test ID: 2019-08-30-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-09-09
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: RM
Date of test: 09/09/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 85778 lb
Maximum load on cylinder 2: 86762 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 10 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.54 in^2
Cross sectional area of cylinder 2: 28.54 in^2
Compressive strength of cylinder 1: 3005.5 psi
Compressive strength of cylinder 2: 3040.0 psi
Compressive strength (to nearest 10 psi): 3020 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 9/9/2019 ✔