Summary for Test 2019-07-30-11-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214032
DEA: 09378604
EFIS: 0918000080
DIST-CO-RTE-PM09-KER-58-R128.9/R135.1
Award Date05/13/2019
Closeout Date12/02/2019
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA.
Location DescriptionKERN COUNTY NEAR BORON FROM 1.3 MILES EAST OF CALIFORNIA CITY BOULEVARD TO 1.3 MILES WEST OF TWENTY MULE TEAM OVERCROSSING
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/30/2019 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R25
The quantity of what the sample constitutesJMF 9 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byLucas
Title of sampler Telephone number of sampler
Laboratory sample identification0468A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Little Rock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0008::LITTLEROCK
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample1468
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Granite Little Rock Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-07-30-11
DIME Test ID: 2019-07-30-11-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-08-22

Test Results


Input Type: Measured
Tester's full name: Michael Magana
Date of test: 08/09/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 977.4 grams
Mass of the pycnometer with water (B): 663.7 grams
Mass of the oven dried sample (before pycnometer) (A): 492.5 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 492.5 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.644
Bulk specific gravity (SSD Basis): 2.684
Apparent specific gravity: 2.754
Absorption: 1.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019