Summary for Test 2019-07-24-10-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 213002 DEA: 042640N4 EFIS: 0412000649 |
---|---|
DIST-CO-RTE-PM | 04-MRN,SON-101-MRN27.0/27.6SON0.0/4.5 |
Award Date | 04/09/2018 |
Closeout Date | 03/12/2021 |
Work Description | CONSTRUCT HOV LANES |
Location Description | MARIN AND SONOMA COUNTIES IN AND NEAR PETALUMA FROM 0.6 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE TO 0.3 MILE SOUTH OF EAST WASHINGTON STREET OVER CROSSING |
QA Service Level | 1 (Verified on 04/13/2018) |
Sample Information
Sample Taken Date | 07/24/2019 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2019 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | three cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | P | Last name of sampler or witnessed by | Latasa |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | 280667 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 4201A |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | Unknown |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Job site | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-07-24-10
DIME Test ID: 2019-07-24-10-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-08-21
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: JK
Date of test: 08/21/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 69263 lb
Maximum load on cylinder 2: 73013 lb
Maximum load on cylinder 3: 73250 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.62 in^2
Cross sectional area of cylinder 3: 12.62 in^2
Compressive strength of cylinder 1: 5514.6 psi
Compressive strength of cylinder 2: 5785.5 psi
Compressive strength of cylinder 3: 5804.3 psi
Compressive strength (to nearest 10 psi): 5700 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 3
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 3
Source: Partner Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 8/21/2019 ✔