Summary for Test 2019-07-08-12-10
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 214343 DEA: 081K5204 EFIS: 0819000058 |
---|---|
DIST-CO-RTE-PM | 08-RIV-243,243-0/28,47/70, 0.0/28 & 47/70 |
Award Date | 02/15/2019 |
Closeout Date | 06/30/2021 |
Work Description | Roadway Washout- Repair storm damage including roadway washout and and damaged pavemetn, embankment, guardrail,m and culverts |
Location Description | Near Banning and on Route 74 near Hermet |
QA Service Level | 1 (Verified on 06/24/2021) |
Sample Information
Sample Taken Date | 07/08/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2019 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A-SP R12 |
The quantity of what the sample constitutes | JMF 9 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Matich Cabazon | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0409A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Robertsons Cabazon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0008::CABAZON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R12 | The fabricator/manufacturer designation for the sample | CHP-62D |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at Matich Cabazon Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-07-08-12
DIME Test ID: 2019-07-08-12-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-08-22
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Husni Ankir, Juan Le Roy
Date of test: 07/17/2019
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 82 %
Cumulative percent passing the 3/8 in. sieve: 70 %
Cumulative percent passing the #4 sieve: 51 %
Cumulative percent passing the #8 sieve: 38 %
Cumulative percent passing the #16 sieve: 29 %
Cumulative percent passing the #30 sieve: 21 %
Cumulative percent passing the #50 sieve: 14 %
Cumulative percent passing the #100 sieve: 9 %
Cumulative percent passing the #200 sieve: 4.8 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate/RAP gradation w/Correlation Factors Applied
Test was verified on 8/22/2019 ✔