Summary for Test 2019-08-03-2-6

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213647
DEA: 080N9724
EFIS: 0815000102
DIST-CO-RTE-PM08-SBD-395-35.5/39.1
Award Date12/03/2018
Closeout Date12/02/2019
Work DescriptionCONSTRUCT MEDIAN AND WIDENING SHOULDER
Location DescriptionSAN BERNARDINO COUNTY NEAR ADELANTO FROM 1.3 MILES SOUTH TO 2.3 MILES NORTH OF KRAMER ROAD
QA Service Level1 (Verified on 03/05/2019)

Sample Information

Sample Taken Date08/03/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/05/2019
Sample typeVerification A brief description of the sample1/2 RHMA-G-SP
The quantity of what the sample constitutesPSE 11 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byLarry Last name of sampler or witnessed byAllan
Title of sampler Telephone number of sampler
Laboratory sample identification0463G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameOro Grande, White Mountain, Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Oro Grande, White Mountain
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample300191-LSM
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-08-03-2
DIME Test ID: 2019-08-03-2-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-08-22

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 08/07/2019
Clay Level (Test 1): 5.6
Sand Level (Test 1): 4
Clay Level (Test 2): 5.4
Sand Level (Test 2): 3.8
Clay Level (Test 3): 5.7
Sand Level (Test 3): 3.9
Sand Equivalent (Test 1): 72
Sand Equivalent (Test 2): 71
Sand Equivalent (Test 3): 69
Sand Equivalent: 71
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019