Summary for Test 2019-06-11-19-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212562
DEA: 024G5504
EFIS: 0214000036
DIST-CO-RTE-PM02-SIS-5-2.7/R11.4
Award Date03/12/2018
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS
Location DescriptionSISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS
QA Service Level1 (Verified on 04/04/2018)

Sample Information

Sample Taken Date06/11/2019 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/12/2019
Sample typeVerification A brief description of the sampleTreated Virgin 3/4-inch Type A Aggregate
The quantity of what the sample constitutesJMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byJohn Last name of sampler or witnessed byCarmichael
Title of sampler Telephone number of sampler
Laboratory sample identificationD77929A Linked DIME Sample ID
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt Transportation Laboratory (TL) Number991051
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0017::FAWNDALE ROCK QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample18-1001.305-23.6_
The plant numberUnknown A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 18-03-R1 Lot number0
Sublot number0 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-11-19
DIME Test ID: 2019-06-11-19-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-07-26

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: D. Valasek and T. McCormick
Date of test: 06/13/2019
Cumulative Mass RetainedCumulative Percent Passing
5706.9 grams
0.0 grams100 %
0.0 grams100 %
24.0 grams99.6 %
1053.0 grams81.5 %
1758.0 grams69.2 %
2438 grams57.3 %
2872.0 grams49.7 %
199.4 grams30.5 %
320.5 grams18.9 %
386.5 grams12.5 %
423.3 grams9 %
445.8 grams6.8 %
460.2 grams5.45 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/26/2019