Summary for Test 2019-07-09-7-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213647
DEA: 080N9724
EFIS: 0815000102
DIST-CO-RTE-PM08-SBD-395-35.5/39.1
Award Date12/03/2018
Closeout Date12/02/2019
Work DescriptionCONSTRUCT MEDIAN AND WIDENING SHOULDER
Location DescriptionSAN BERNARDINO COUNTY NEAR ADELANTO FROM 1.3 MILES SOUTH TO 2.3 MILES NORTH OF KRAMER ROAD
QA Service Level1 (Verified on 03/05/2019)

Sample Information

Sample Taken Date07/09/2019 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/10/2019
Sample typeVerification A brief description of the sample1/2 HMA-A-SP R15
The quantity of what the sample constitutesPSE 14 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byA S Last name of sampler or witnessed bySAMANO MAQUIBAN
Title of sampler Telephone number of sampler
Laboratory sample identification0410A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAgcon Inc Oro Grande, Cemex White Mountain Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0046, 91-36-0106
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample300215
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-07-09-7
DIME Test ID: 2019-07-09-7-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-08-22

Test Results


Input Type: Measured
Tester's full name: Nader Rashidi
Date of test: 07/16/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965 grams
Mass of the pycnometer with water (B): 655 grams
Mass of the oven dried sample (before pycnometer) (A): 491.6 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.6 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.587
Bulk specific gravity (SSD Basis): 2.632
Apparent specific gravity: 2.707
Absorption: 1.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019