Summary for Test 2019-06-27-18-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213551 DEA: 080K2934 EFIS: 0812000100 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-R36.8/R39.2 |
Award Date | 11/09/2018 |
Closeout Date | 09/15/2021 |
Work Description | PAVEMENT REHABILITATION AND CONTINUOUSLY REINFORCED CONCRETE PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN YUCAIPA FROM 0.2 MILE WEST OF LIVE OAK CANYON ROAD TO COUNTY LINE ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 06/27/2019 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2019 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A R12 PG64-28M |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | unknown | Last name of sampler or witnessed by | unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Matich-Lytle Creek | Transportation Laboratory (TL) Number | 0394A-19 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 18 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-06-27-18
DIME Test ID: 2019-06-27-18-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-07-11
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 07/02/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 0.0 g
Mass Loss: 0.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: no data
Corrected Asphalt Binder Content: 4.27 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/11/2019 ✔