Summary for Test 2019-06-29-1-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213647 DEA: 080N9724 EFIS: 0815000102 |
---|---|
DIST-CO-RTE-PM | 08-SBD-395-35.5/39.1 |
Award Date | 12/03/2018 |
Closeout Date | 12/02/2019 |
Work Description | CONSTRUCT MEDIAN AND WIDENING SHOULDER |
Location Description | SAN BERNARDINO COUNTY NEAR ADELANTO FROM 1.3 MILES SOUTH TO 2.3 MILES NORTH OF KRAMER ROAD |
QA Service Level | 1 (Verified on 03/05/2019) |
Sample Information
Sample Taken Date | 06/29/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2019 |
Sample type | Department Acceptance | A brief description of the sample | 1" HMA-A R15 PG 64-28M |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0397A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-06-29-1
DIME Test ID: 2019-06-29-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-07-11
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Cristina Paredes
Date of test: 07/03/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 0.0 g
Mass Loss: 0.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: no data
Corrected Asphalt Binder Content: 4.35 %
General comments (publicly viewable) (Max 1000 characters):