Summary for Test 2019-06-27-10-2
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 213569 DEA: 024F2104 EFIS: 0212000072 |
---|---|
DIST-CO-RTE-PM | 02-MOD-299-0.5/1.0 |
Award Date | 12/20/2018 |
Closeout Date | 11/15/2021 |
Work Description | Butte and Ash Creek Bridge Replacement |
Location Description | Construction of Butte Creek Bridge and Ash Creek Bridge on Route 299 at Adin |
QA Service Level | 1 (Verified on 06/26/2019) |
Sample Information
Sample Taken Date | 06/27/2019 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/03/2019 |
Sample type | Quality Assurance | A brief description of the sample | End Anchors |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | R | Last name of sampler or witnessed by | Duran |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Barsplice | Transportation Laboratory (TL) Number | C897176 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 175419 | Head Manufacturer Lot Number(s) | Barsplice |
Rebar Size | 4 | Headed Bar Model Name | Barsplice Buttonhead 10AB |
Size of Head | Full Size - 9x | Head Connection Type | Crimped Head |
Head Shape | Circular | Rebar Manufacturer | Cascade |
Head Manufacturer | Barsplice | Head Fabricator | Unknown |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2019-06-27-10
DIME Test ID: 2019-06-27-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-07-10
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/03/2019
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 0.2 | 18820 | 94100 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/10/2019 ✔