Summary for Test 2019-04-17-40-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/17/2019 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2019 |
Sample type | Quality Control | A brief description of the sample | 3/4 inch HMA-SP |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Escobar |
Title of sampler | QA Technician | Telephone number of sampler | 209-234-3571 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-17-40
DIME Test ID: 2019-04-17-40-4
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-07-02
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Gurpartap Grewal
Date of test: 04/17/2019
Percent Air Voids: 3.7 %
Percent Air Voids 2: 3.5 %
Percent Air Voids 3: 3.6 %
Percent Air Voids Average: 3.6 %
General comments (publicly viewable) (Max 1000 characters): HMA Design Data T-269
Test was verified on 7/2/2019 ✔