Summary for Test 2019-06-20-30-1

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 212911
DEA: 081F9404
EFIS: 0815000067
DIST-CO-RTE-PM08-RIV-79-R4.7/R10.6
Award Date05/22/2018
Closeout Date06/23/2021
Work DescriptionCOLD PLANE, OVERLAY WITH RUBBERIZED HOT MIX ASPHALT (TYPE G)
Location DescriptionRIVERSIDE COUNTY FROM 0.1 MILE SOUTH OF MURRIETA HOT SPRINGS ROAD TO 0.1MILE NORTH OF ABELIA ROAD
QA Service Level1 (Verified on 12/28/2018)

Sample Information

Sample Taken Date06/20/2019 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2019
Sample typeAcceptance A brief description of the sample3/4 inch combined agg
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byQC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameR J Noble Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0014::CHANDLER - COLDWATER
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G The fabricator/manufacturer designation for the sample49R003ARSP-C
The plant numberUnknown A detailed description of where the material sample was collectedHMA Plant Cold Feed
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-20-30
DIME Test ID: 2019-06-20-30-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-07-02

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: I. NAJJAR
Date of test: 06/21/2019
Sand Equivalent (Test 1): 84
Sand Equivalent (Test 2): 78
Sand Equivalent (Test 3): 83
Sand Equivalent: 82
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2019