Summary for Test 2019-05-30-12-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date05/30/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R21
The quantity of what the sample constitutesPSE 6 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byJonathan Last name of sampler or witnessed byArthur
Title of samplerVulcan Irwindale QC Telephone number of sampler
Laboratory sample identification0345A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameReliance Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0018::RELIANCE- AZUSA
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R21 The fabricator/manufacturer designation for the sample220817 IRW SJR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-05-30-12
DIME Test ID: 2019-05-30-12-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-07-03

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 06/14/2019
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 74 %
Cumulative percent passing the 3/8 in. sieve: 62 %
Cumulative percent passing the 1/4 in. sieve: 62 %
Cumulative percent passing the #4 sieve: 44 %
Cumulative percent passing the #8 sieve: 30 %
Cumulative percent passing the #16 sieve: 21 %
Cumulative percent passing the #30 sieve: 14 %
Cumulative percent passing the #50 sieve: 9 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2019