Summary for Test 2019-06-04-13-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214102 DEA: 043Q9404 EFIS: 0419000285 |
---|---|
DIST-CO-RTE-PM | 04-CC,CC,MRN-580-6.1/7.8, 0/2.7 |
Award Date | 03/18/2019 |
Closeout Date | 09/16/2020 |
Work Description | Emergency joint replacement project |
Location Description | Richmond San Rafael Bridge |
QA Service Level | 1 (Verified on 03/04/2019) |
Sample Information
Sample Taken Date | 06/04/2019 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/17/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 TC Bolts |
The quantity of what the sample constitutes | 25 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Unytite Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 10563900 10548720 20324840 | Nut Mfg. Lot Number(s) | 29196-75072563 28486-188310 19137-144120 |
Washer Mfg. Lot Number(s) | D6098 D5666 C8172M | Bolt Specification | A325 TC MG |
Bolt Length(s) | 2" 2.5" | Nut Specification | A563 DH MG |
Washer Specification | F436 MG | Finish | MG |
Diameter/Size | 7/8" 1" | Bolt Mfg. Lot Number | 29205-10563900 28716-10548720 19283-203248 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-06-04-13
DIME Test ID: 2019-06-04-13-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-06-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 06/19/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 3A | 19137-144120 | 1\" | 93742 | 416.99 | Nut Proof Load | Steve |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 6/20/2019 ✔