Summary for Test 2019-04-02-11-4
Test performed: AASHTO T283-14Project Information
Project Identifiers | Project ID: 213912 DEA: 033H71U4 EFIS: 0319000051 |
---|---|
DIST-CO-RTE-PM | 03-BUT-70-8.8/12.1 |
Award Date | 05/09/2019 |
Closeout Date | 09/23/2021 |
Work Description | WIDEN RDWY, RDWY EX, HMA & MODIFY ELECT SYSTEM. |
Location Description | BUTTE COUNTY NEAR OROVILLE FROM 0.1 MILE SOUTH OF PALERMO ROAD TO 0.6 MILE NORTH OF OPHIR ROAD |
QA Service Level | 1 (Verified on 02/21/2019) |
Sample Information
Sample Taken Date | 04/02/2019 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2019 |
Sample type | Quality Control | A brief description of the sample | QC for Assembling JMF |
The quantity of what the sample constitutes | 500 tons | From where was the sample collected | Source |
First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Blumer |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Materials Hallwood | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-02-11
DIME Test ID: 2019-04-02-11-4
Testing Lab: Teichert Materials - Sacramento
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2019-06-05
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Eric Gifford
Date of test: 04/02/2019
Specimen Treatment: Untreated
Average Dry Tensile Strength: 217 psi
Average Wet Tensile Strength: 193 psi
Tensile Strength Ratio: 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2019 ✔