Summary for Test 2019-05-06-2-1
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 209695 DEA: 08347704 EFIS: 0800000616 |
---|---|
DIST-CO-RTE-PM | 08-SBD-SR-58-0/12.9 |
Award Date | 11/10/2017 |
Closeout Date | 01/14/2021 |
Work Description | (Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395. |
Location Description | SR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395. |
QA Service Level | 1 (Verified on 12/01/2017) |
Sample Information
Sample Taken Date | 05/06/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/10/2019 |
Sample type | Quality Assurance | A brief description of the sample | A722 Threaded Bar |
The quantity of what the sample constitutes | 68487 lbs | From where was the sample collected | Source |
First name of sampler or witnessed by | Clifford | Last name of sampler or witnessed by | William |
Title of sampler | QA Inspector | Telephone number of sampler | 7142674733 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Dywidag Systems | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-022-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Rebar Size | ||
Nut Specification for Threaded Bar | A29 Grade 1045 | System Manufacturer | Dywidag Systems |
Epoxy Coating Color | NA | Threaded Bar Application | |
Coating Standards | Uncoated | Bar Heat Number(s) | 62148300 |
Nut Heat Number(s) | 62146003 | Bar Lot Number | |
Nut Lot Number | Coupler Heat Number(s) | ||
Coupler Grade |
Test Details
DIME Sample ID: 2019-05-06-2
DIME Test ID: 2019-05-06-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2019-05-29
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/21/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | A722 DSI 1.250\" Threaded Bar & Nut | NA | 1 | 167363 | 155694 | 0 | 32.1 | A722 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/22/2019 ✔