Summary for Test 2019-03-25-25-1

Test performed: AASHTO T308-10
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/25/2019 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2019
Sample typeVerification A brief description of the sample1/2 inch Type A (PG 64-10) (Dispute Resolution of JMF)
The quantity of what the sample constitutesDispute Resolution of JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byMark Last name of sampler or witnessed byHuddleston
Title of samplerMat and Res Eng Aso Telephone number of sampler
Laboratory sample identification019-006 Linked DIME Sample IDNA
The fabricator/manufacturer/facility namePapich Construction Transportation Laboratory (TL) NumberHDQTRS Lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-25-25
DIME Test ID: 2019-03-25-25-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-05-15

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Frank Chavez
Date of test: 04/30/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1505.4 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1397.2 g
Correction Factor (Percent by mass of HMA Specimen): 1.13 %
Moisture Content: 0.24 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.82 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/8/2019

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.