Summary for Test 2017-04-03-13-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 213793 DEA: 060W7004 EFIS: 0617000283 |
---|---|
DIST-CO-RTE-PM | 06-FRE-33-24.3/R29.0,R39.9/44.5 |
Award Date | 01/24/2019 |
Closeout Date | 08/20/2021 |
Work Description | COLD PLANE AC PAVEMENT, PLACE HMA RESURFACING. |
Location Description | FRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD |
QA Service Level | 1 (Verified on 01/09/2019) |
Sample Information
Sample Taken Date | 04/03/2017 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2017 |
Sample type | Quality Control | A brief description of the sample | Bin #4 RD untreated (Dispute Resolution) |
The quantity of what the sample constitutes | JMF HMA Design Data (Dispute Resolution) | From where was the sample collected | Source |
First name of sampler or witnessed by | SPM | Last name of sampler or witnessed by | Avenal |
Title of sampler | NA | Telephone number of sampler | 805-473-3016 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SPM-Avenal | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006::AVENAL AGGREGATES |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | SPM-Avenal | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2017-04-03-13
DIME Test ID: 2017-04-03-13-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-08
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: G3 Quality, Inc.
Date of test: 04/03/2017
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the 1/4 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 98 %
Cumulative percent passing the #8 sieve: 81 %
Cumulative percent passing the #16 sieve: 62 %
Cumulative percent passing the #30 sieve: 48 %
Cumulative percent passing the #50 sieve: 38 %
Cumulative percent passing the #100 sieve: 27 %
Cumulative percent passing the #200 sieve: 20.3 %
General comments (publicly viewable) (Max 1000 characters): JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
Test was verified on 5/1/2019 ✔