Summary for Test 2019-01-04-77-6
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/04/2019 | Sample Unique Key | 77 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/10/2019 |
Sample type | Quality Control | A brief description of the sample | JMF 1/2 HMA |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Ruedi |
Title of sampler | Telephone number of sampler | 925-260-3017 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Materials - Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010::CALMAT/PLEASANTON |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | 1 | |
Sublot number | 1 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-01-04-77
DIME Test ID: 2019-01-04-77-6
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-05-20
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Gurpartap Grewal
Date of test: 01/04/2019
Bulk dry specific gravity: 2.606
Average uncompacted voids: 45.5 %
General comments (publicly viewable) (Max 1000 characters): Aggregate Quality T 304
Test was verified on 5/13/2019 ✔