Summary for Test 2019-04-01-6-8

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date04/01/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2019
Sample typeVerification A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byHindman
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2019-04-01-5
The fabricator/manufacturer/facility nameRobertsons Lucern Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91360116
The fabricator's/manufacturer's product name for the sampleRobertsons Lucerne Quarry The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedWashed Concrete Sand
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-01-6
DIME Test ID: 2019-04-01-6-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-04-30

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Danny Ferrer
Date of test: 04/05/2019
Temperature correction: 0
Temperature of solution: 23
Clay reading (test 1): 4.8
Sand reading (test 1): 4.2
Clay reading (test 2): 4.7
Sand reading (test 2): 4
Sand equivalent (test 1): 88
Sand equivalent (test 2): 86
Sand equivalent before temperature correction: 87
Sand equivalent after temperature correction: 87
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/23/2019