Summary for Test 2019-03-13-15-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/13/2019 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2019 |
Sample type | Verification | A brief description of the sample | Boxes of HMA, Cans of Asphalt and LAS |
The quantity of what the sample constitutes | 1/4 of Section 39 JMF verification samples | From where was the sample collected | Other |
First name of sampler or witnessed by | Brent | Last name of sampler or witnessed by | Barber |
Title of sampler | Field Inspector | Telephone number of sampler | 805-4410187 |
Laboratory sample identification | 19-J-015 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Papich Paso Robles | Transportation Laboratory (TL) Number | D5 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-03-13-15
DIME Test ID: 2019-03-13-15-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-04-22
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Eric Atkins
Date of test: 04/19/2019
Bulk Specific Gravity: 2.392
Bulk Specific Gravity 2: 2.395
Bulk Specific Gravity 3: 2.396
Theoretical Maximum Specific Gravity: 2.456
Percent Air Voids: 2.6 %
Percent Air Voids 2: 2.5 %
Percent Air Voids 3: 2.4 %
Percent Air Voids Average: 2.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/22/2019 ✔