Summary for Test 2014-04-18-13357845-2
Test performed: ASTM C143-10aProject Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 04/18/2014 | Sample Unique Key | 13357845 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/19/2014 |
Sample type | Verification | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 5 concrtete cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Aston | Last name of sampler or witnessed by | James |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | RW 311R | |
Structure name | RW 311R |
Material Information
Material Type | Concrete | The concrete mix design number | 103612F |
---|---|---|---|
The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 110694 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | Chute | Where the material sample would have been placed if not sampled | RW 311R Soundwall btwn STA 1218.23 and 1265.44 |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-04-18-13357845
DIME Test ID: 2014-04-18-13357845-2
Testing Lab: Leighton Consulting, Incorporated - San Diego
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Test Release Date: 2014-07-08
Test Results
Input Type: Measured
Tester's full name: Aston James
Date of test: 04/18/2014
Slump: 4 inch
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/8/2014 ✔