Summary for Test 2019-02-04-2-5
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 02/04/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/04/2019 |
Sample type | Quality Assurance | A brief description of the sample | 1" A325 TC Bolt assy |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 702 917-2503 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Le Jeune | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-010-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | ||
Washer Mfg. Lot Number(s) | Bolt Specification | A325-TC | |
Bolt Length(s) | 2-1/4, 3-1/4, 4" and 4-1/2 | Nut Specification | A563 |
Washer Specification | F436 | Finish | |
Diameter/Size | 1" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-02-04-2
DIME Test ID: 2019-02-04-2-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-02-27
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/19/2019
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 4A | 29714-10570770 | 1\" | 94293 | 419.4 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 2/20/2019 ✔