Summary for Test 2019-02-11-4-2

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 213474
DEA: 010A8404
EFIS: 0113000058
DIST-CO-RTE-PM01-MEN-271-17.7/18.0
Award Date09/14/2018
Closeout Date12/04/2019
Work DescriptionBRIDGE REPLACEMENT, ROADWAY REALIGNMENT AND WIDENING.
Location DescriptionMENDOCINO COUNTY NEAR PIERCY FROM 0.7 MILE NORTH OF HIGHWAY 271/101 SEPARATION TO 0.4 MILE SOUTH OF THE SIDEHILL VIADUCT
QA Service Level1 (Verified on 08/24/2018)

Sample Information

Sample Taken Date02/11/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/14/2019
Sample typeQuality Assurance A brief description of the samplebearing pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byPete Last name of sampler or witnessed byEtcheverry
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)17298-1
Material/Compound/Elastomer IDna Samples Representing17
Description (size)2" x 18" x 18" CommentsUnknown
Description (Number of Shims)4 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch Numberna

Test Details

DIME Sample ID: 2019-02-11-4
DIME Test ID: 2019-02-11-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2019-03-11

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Calculated
Tester's full name: Steve
Date of test: 02/15/2019
UTM: 11KIP
Humidity: 50 %
Temperature: no data
Sample 1 Median Thickness: 0.064 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2693.8 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.073 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2776 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.064 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2581.3 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2693.8 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 3/4/2019