Summary for Test 2019-02-06-1-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213474 DEA: 010A8404 EFIS: 0113000058 |
---|---|
DIST-CO-RTE-PM | 01-MEN-271-17.7/18.0 |
Award Date | 09/14/2018 |
Closeout Date | 12/04/2019 |
Work Description | BRIDGE REPLACEMENT, ROADWAY REALIGNMENT AND WIDENING. |
Location Description | MENDOCINO COUNTY NEAR PIERCY FROM 0.7 MILE NORTH OF HIGHWAY 271/101 SEPARATION TO 0.4 MILE SOUTH OF THE SIDEHILL VIADUCT |
QA Service Level | 1 (Verified on 08/24/2018) |
Sample Information
Sample Taken Date | 02/06/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/08/2019 |
Sample type | Quality Assurance | A brief description of the sample | #11 Ultimate Butt Splice |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 702 917-2503 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Camblin Steel | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-011-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 11 | Coupler Model | Grip Twist |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A181588, A172211, A172036 | Rebar Heat Number(s) | 65031565 02 |
Rebar Size 2 | 11 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2019-02-06-1
DIME Test ID: 2019-02-06-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-02-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/11/2019
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #11/36mm | 1.56 | -0.0015 | 146020 | 93603 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/12/2019 ✔