Summary for Test 2019-01-21-14-4

Test performed: AASHTO T269-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date01/21/2019 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/06/2018
Sample typeQuality Control A brief description of the sampleLaboratory-Batched 3/4-inch Type A HMA (eq. PG 64-10/16)
The quantity of what the sample constitutesMix Design From where was the sample collectedOther
First name of sampler or witnessed byCGI Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identification19-1001 314 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt - Redding, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number0
Sublot number0 HMA Mix NumberNot set

Test Details

DIME Sample ID: 2019-01-21-14
DIME Test ID: 2019-01-21-14-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-02-06

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: CGI
Date of test: 01/21/2019
Percent Air Voids: 3.7 %
Percent Air Voids 2: 3.7 %
Percent Air Voids 3: 3.8 %
Percent Air Voids Average: 3.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/6/2019

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.