Summary for Test 2019-01-16-12-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 |
---|---|
DIST-CO-RTE-PM | 10-SJ-5-26.5/27.0 |
Award Date | 03/02/2017 |
Closeout Date | 01/24/2020 |
Work Description | REPAIR BRIDGE CROSSFRAMES. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT |
QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
Sample Taken Date | 01/16/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | QAI | Telephone number of sampler | 510-693-3545 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-005-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 304-19-4 |
---|---|---|---|
Heat Number(s) | 100890078 | Nut Mfg. Lot Number(s) | 411793D |
Washer Mfg. Lot Number(s) | 0818-936 | Bolt Specification | A325 |
Bolt Length(s) | 7-1/2" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 404913 |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2019-01-16-12
DIME Test ID: 2019-01-16-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-02-01
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/25/2019
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 5A | 404913A | 1\" | 87394 | 388.7 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 1/25/2019 ✔