Summary for Test 2018-10-01-13-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 213002 DEA: 042640N4 EFIS: 0412000649 |
---|---|
DIST-CO-RTE-PM | 04-MRN,SON-101-MRN27.0/27.6SON0.0/4.5 |
Award Date | 04/09/2018 |
Closeout Date | 03/12/2021 |
Work Description | CONSTRUCT HOV LANES |
Location Description | MARIN AND SONOMA COUNTIES IN AND NEAR PETALUMA FROM 0.6 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE TO 0.3 MILE SOUTH OF EAST WASHINGTON STREET OVER CROSSING |
QA Service Level | 1 (Verified on 04/13/2018) |
Sample Information
Sample Taken Date | 10/01/2018 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/19/2018 |
Sample type | Quality Assurance | A brief description of the sample | type II/V |
The quantity of what the sample constitutes | 2 6x12 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Melvin | Last name of sampler or witnessed by | Dumlao |
Title of sampler | ASR | Telephone number of sampler | 5107147638 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | shamrock materials | Transportation Laboratory (TL) Number | 502 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | RW 113 |
Structure name | RW 113 |
Material Information
Material Type | Concrete | The concrete mix design number | 4201a |
---|---|---|---|
The truck number from where the sample was collected | 1418 | The batch plant ticket number from where the sample was collected | 170911 |
Concrete batch plant | shamrock materials petaluma | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | back of truck | Where the material sample would have been placed if not sampled | RW 113 Stem Wall |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-10-01-13
DIME Test ID: 2018-10-01-13-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-10-29
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: RM
Date of test: 10/29/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 145012 lb
Maximum load on cylinder 2: 144946 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.56 in^2
Compressive strength of cylinder 1: 5095.3 psi
Compressive strength of cylinder 2: 5075.1 psi
Compressive strength (to nearest 10 psi): 5090 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 10/29/2018 ✔