Summary for Test 2018-10-05-18-5
Test performed: AASHTO T283-14Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 10/05/2018 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/03/2018 |
Sample type | Quality Control | A brief description of the sample | THINH |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | THINH | Last name of sampler or witnessed by | NGUYEN |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | AAAA | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Not set |
Sublot number | Not set | HMA Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-10-05-18
DIME Test ID: 2018-10-05-18-5
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2018-10-26
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: David Phong
Date of test: 10/03/2018
Specimen Treatment: Treated
Average Dry Tensile Strength: 135.2 psi
Average Wet Tensile Strength: 126.1 psi
Tensile Strength Ratio: 1
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2018 ✔