Summary for Test 2018-10-05-6-1

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date10/05/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/05/2018
Sample typeQuality Assurance A brief description of the sample1 1/4 thread bar
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byTory Last name of sampler or witnessed byMcLaurin
Title of samplerQA Telephone number of sampler6616185971
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDSI Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL67-098-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size10
Nut Specification for Threaded BarA519, A521 System ManufacturerGerdau
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62142851/04
Nut Heat Number(s)49655, EH Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-10-05-6
DIME Test ID: 2018-10-05-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-10-24

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/17/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11A722 DSI 1.250\" Threaded Bar & NutL67-098-181.011159975142288035.5A722 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/17/2018