Summary for Test 2018-09-20-2-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 212743
DEA: 030H26U4
EFIS: 0317000247
DIST-CO-RTE-PM03-PLA-65-R5.0/R6.6
Award Date02/14/2018
Closeout Date10/21/2022
Work DescriptionNORTHBOUND WIDENING AND RAMP IMPROVEMENTS.
Location DescriptionPLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/18/2017)

Sample Information

Sample Taken Date09/20/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/20/2018
Sample typeQuality Assurance A brief description of the sampleHRC 120 End Anchors
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byTory Last name of sampler or witnessed byMcLaurin
Title of samplerQA Telephone number of sampler6616185971
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL67-083-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)xxxx Head Manufacturer Lot Number(s)xxxx
Rebar Size5 Headed Bar Model NameHRC 120
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeCircular Rebar Manufacturerxxxxx
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2018-09-20-2
DIME Test ID: 2018-09-20-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-10-16

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/09/2018
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.312977096030Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/9/2018