Summary for Test 2018-09-11-11-43

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date09/11/2018 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/25/2018
Sample typeIndependent Assurance A brief description of the sampleHS fasteners for T17
The quantity of what the sample constitutesmulitiple lots From where was the sample collectedJob Site
First name of sampler or witnessed bygreg Last name of sampler or witnessed byjohnston
Title of samplerIQA Telephone number of sampler9165247768
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Bolt Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL53-050-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)2714910502870 1412808 1412843 1412815 1412844 1412816 1412817 1412822 1412823
Heat Number(s) Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF3125
Bolt Length(s) Nut SpecificationA563
Washer SpecificationF436 Finishgeomet
Diameter/Size3/4x2 1/4; 1x3 1/2; 1 1/4x6; 1 1/4x6 1/2; 1 1 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2018-09-11-11
DIME Test ID: 2018-09-11-11-43
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-10-12

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 10/03/2018
Sample No.: 3A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 28748-10558400Z
Finish Coating: ASTM F1136 - Dachromet or Geomet
Product Markings: A490 USA
Size: 1.25 in
Bolt Length: 5.5 in
Measurement Average: 0.76 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/5/2018