Summary for Test 2018-09-11-4-82
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 09/11/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/25/2018 |
Sample type | Independent Assurance | A brief description of the sample | HS fasteners for T16 |
The quantity of what the sample constitutes | multiple lots | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
Title of sampler | IQA | Telephone number of sampler | 9165247768 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Lejune | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L53-050-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 2714110502870 2714910502870 2804410537450 2805310537450 2719210518550 2805510537450 2805610537450 2805710537450 2805810541510 2806010541510 2806110541510 2806210541510 2806410541510 2806510541510 1412815 1412747 1412619 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | ||
Washer Mfg. Lot Number(s) | Bolt Specification | F3125 | |
Bolt Length(s) | Nut Specification | A563 DH | |
Washer Specification | F436 | Finish | Geomet |
Diameter/Size | 3/4x2; 3/4x2 1/4; 1x2 1/2; 1x3 1/4: 1x3 1/2; | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-09-11-4
DIME Test ID: 2018-09-11-4-82
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-10-12
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 10/02/2018
Sample No.: 2A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 27149-10502870
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325TC USA
Size: .75 in
Bolt Length: 2.25 in
Measurement Average: 3.96 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/5/2018 ✔