Summary for Test 2018-09-13-4-3

Test performed: ASTM A775-07b-re14

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date09/13/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/19/2018
Sample typeQuality Assurance A brief description of the sampleGreen Epoxy Coated Rebar
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byLaLo Last name of sampler or witnessed byRomero
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWestern Coating, Gerdau, Nucor Transportation Laboratory (TL) NumberC
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)65030262, PL17107178, 1201003799, PL17107111
Rebar Epoxy Batch Number(s) Rebar Coating SpecificationASTM A775
Rebar Size (#)6, 8, 10 Rebar Coating ColorGreen
Rebar ManufacturerGerdau Nucor Rebar CoaterWestern Coating
Rebar Powder ManufacturerUnknown Release NumberUnknown
Quality Assurance CodeUnknown

Test Details

DIME Sample ID: 2018-09-13-4
DIME Test ID: 2018-09-13-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2018-09-27

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 09/19/2018
Lower spec. limit LSL: 7
Upper spec. limit USL: 16
Bar # for First Bar: 1201003799-1
Bar # for Second Bar: 1201003799-2
First Bar Side 1 mean value: 8.46
First Bar Side 2 mean value: 9.39
Second Bar Side 1 mean value: 9.98
Second Bar Side 2 mean value: 10.64
First Bar Mean: 8.93
Second Bar Mean: 10.31
Total mean value: 9.62
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/20/2018